Logging with Teledyne Optech CL-360HD

RESEPI User Manual

Data Logging and Offloading with Teledyne Optech CL-360HD #

Since firmware version 4.0.0.0, the RESEPI system supports data logging and offloading for the Teledyne Optech CL-360HD. These features are intended for experienced users and are not recommended for beginners. Follow the steps below to collect and offload data:

  1. Power On the Unit

    • Start by powering up the RESEPI Teledyne Optech CL-360HD unit.
  2. Connect to a Computer

    • Use a data cable with a LEMO connector (part number: FGG.0T.309 or a compatible connector) connected to an RJ45 ethernet cable to link the Teledyne Optech scanner to a computer.
    • Note: For detailed instructions on connecting to the Teledyne Optech CL-360HD, refer to the Teledyne Optech CL-360HD Integration Manual.
  3. Verify Connection

    • Open a web browser on the computer and navigate to the IP address: 192.168.219.150. This should display Optech’s web GUI.
  4. Configure Settings

    • Within the web GUI, configure settings according to the owner’s manual provided by Teledyne for the Optech CL-360HD.
    • Enable logging as required, then proceed with data acquisition. Once acquisition is complete, move on to the next step.
    • Note: It is advisable to perform a bench test before field acquisitions to ensure proper configuration of settings.
  5. Connect Using FTP Client

    • Open an FTP client and connect to the scanner using the following details:
      • IP Address: 192.168.219.150
      • Username: public
      • Password: public
  6. Locate Scanned Projects

    • After connecting via FTP, navigate to the /PROJECTS directory and locate the /SURVEYS folder where scanned projects are stored.
  7. Transfer or Delete Data

    • Transfer and/or delete data from the folder as needed.

By following these steps, you can effectively log and manage data using the Teledyne Optech CL-360HD with the RESEPI system.