Real Time Point Cloud Streaming

RESEPI User Manual

Streaming a Point Cloud from RESEPI #

PCMasterPro (version 1.13 and above) enables RESEPI GEN-II or EchoONE users to stream LiDAR point clouds in real time for immediate visualization and verification during field operations.

As of PCMasterPro 2.0, each LiDAR point is georeferenced live as it arrives. PCMasterPro combines three things from the payload:

  • The LiDAR point stream: the raw scan points.
  • A second INS data stream: the payload’s live INS position and orientation. Each point is placed using the INS solution at the moment that point was captured.
  • The on-unit calibration: the payload’s orientation, boresight, and scanner offset values, which PCMasterPro requests from the payload each time a stream starts.

Each of these uses its own network (UDP) port on the payload’s IP address, and all three can be changed in the streaming dialogue:

SettingDefault PortPurpose
Lidar Port7654LiDAR point cloud stream
INS Port7655Live INS position and orientation stream
Control Port7656Calibration request sent when the stream starts

The defaults normally do not need to be changed. Edit them only if your payload has been set up to use different ports. The payload’s ports are set in its web-GUI under Settings > Connectivity > Live Stream Ports; the values entered in PCMasterPro must match.

To begin streaming the point cloud:

  1. Power on the RESEPI GEN-II or EchoONE unit
    Ensure the system is properly powered up before proceeding.
  2. Establish a connection
    Connect your host device to the RESEPI GEN-II or EchoONE unit using one of the following methods:
    • Wi-Fi: Connect to the RESEPI’s or EchoONE’s broadcasted wireless network.
    • Ethernet: Connect an Ethernet cable directly between the unit and your host device (You can procure a compatible ethernet cable from sales@inertiallabs.com).
  3. Launch the PCMasterPro application
    Open the PCMasterPro software on your device.
  4. Open the Data Streaming dialogue
    In the application, go to Toolkits > Data Streaming. The Point Cloud Streamingdialogue opens. Click Data Streaming again to hide it.
  5. Enter the appropriate IP address
    Depending on your connection method, enter the correct IP address:
    • Wi-Fi: 192.168.12.1 (the dialogue default)
    • Ethernet: 192.168.13.1 when connected to LAN2. If you are using a different LAN interface, enter that interface’s address from the Network Addresses table in Understanding the RESEPI GEN-II Payload.
  6. Confirm the ports
    Leave Lidar Port, INS Port, and Control Port at their defaults (7654, 7655, and 7656) unless your payload uses different ports. The IP address and port fields are locked while a stream is running.
  7. Set the Point Density
    The Point Density slider (1% to 100%, default 25%) sets the percentage of LiDAR points kept. Lower it if the live view falls behind. The setting applies to both the points displayed and the points recorded, so a lower density also produces a sparser saved cloud. It can be adjusted while streaming.
  8. Start the stream
    Click Start Stream. The button changes to Stop Stream, and the status line shows progress. Once Status: Streaming Data appears, the point cloud begins to stream live on your screen, updating in real time as data is captured by the LiDAR.
    StatusMeaning
    Status: Connecting / Status: Requesting data streamPCMasterPro is opening its ports and asking the payload to send data.
    Status: Streaming DataLiDAR data is arriving.
    Status: Waiting for INS/calibration dataLiDAR data is arriving, but the INS stream or the calibration has not been received yet. Points are not displayed until both arrive. Check the IP address, INS Port, and Control Port.
    Error: Failed to fetch calibration from control channelThe payload did not answer the calibration request. Check the IP address and Control Port. PCMasterPro retries automatically every few seconds.
    Error: Failed to bind socketThe Lidar Port could not be opened on this computer. Another program may already be using it.
    Status: IdleNot streaming.
  9. Record and save the stream
    Once streaming has started, click Start Recording (it changes to Stop Recording). When you stop recording, Clear Recording discards the recorded points and Save Recording to LAS saves them in .las format. You will be prompted to choose the location for the saved point cloud. Stopping the stream while recording is active also stops the recording.
Figure: Shows the Point Cloud Streaming dialogue in PCMasterPro