Pre-Recording Checklist

RESEPI User Manual

Pre-Recording Checklist for 360 Camera Scans #

This checklist applies to both mobile mapping (MMS) and SLAM scans that use the GoPro MAX 2 360 camera. It covers the camera only. Complete it together with the Pre-Recording Checklist for the type of scan being performed (RESEPI SOP for Capturing MMS Scans or RESEPI SOP for Capturing SLAM Scans), which covers the RESEPI payload itself.

 

☐ Complete the Payload Checklist

  • MMS scans: complete the MMS Pre-Recording Checklist.
  • SLAM scans: complete the SLAM Pre-Recording Checklist.

☐ Mount the 360 Camera

  • Install the GoPro MAX 2 on the mobile mount (MMS) or the backpack/handheld mount (SLAM) as described in the 360 Camera Mounting for MMS or 360 Camera Mounting for SLAM guide.
  • Confirm the supplied Inertial Labs SD card is inserted in the camera.
  • Confirm the camera is secure and the lens is clean and unobstructed.

☐ Battery and Storage

  • Confirm the camera battery is fully charged.
  • Confirm the SD card has enough free space for the entire recording.

☐ Camera Settings

Set the following on the camera touchscreen:

  • Camera Mode: 360. The camera saves a .360 file.
  • Orientation: All.
  • Profile: Standard.
  • Resolution: 5.6K.
  • Frame Rate: 30 fps.
  • QuikCapture: Off.
  • Scheduled Capture: Off.
  • Duration: Off.
  • Timer: Off.
  • GPS: On.
  • Do not change camera settings between scans of the same project.

☐ GPS Lock

  • Confirm the GPS position icon at the top left of the camera touchscreen is blue, which shows the camera has a GPS fix.
  • Wait for the GPS fix before recording. PCMasterPro uses the camera GPS time to help match the camera clock to the scanner clock.

☐ Camera Date and Time

  • Confirm the camera date and time are correct.

☐ Boresight Calibration on the Payload

  • In the payload web-GUI, go to Settings > Camera and confirm there is an entry for the mount being used:
    • gopro-mms for MMS scans
    • gopro-slam for SLAM scans
  • If it is missing or needs updating, load it with “Read from PCMasterPro .pcpp File”. The calibration stays on the payload until it is overwritten by another calibration.

☐ Recording Order

  • Start the 360 camera recording before starting the RESEPI recording, and stop it only after the RESEPI recording has stopped.
  • Start and stop the RESEPI recording as described in the MMS or SLAM Mission Step-by-Step.

☐ Keep the Lower Image Clear

  • Keep the operator’s body out of the lower part of the image where possible.

☐ Final Check

  • Camera mounted securely with a clean lens.
  • GPS icon blue.
  • Camera settings confirmed.