Before You Start Processing

RESEPI User Manual
Table of contents

Pre-Processing Checklist #

Before beginning data processing, verify the following:

  • PCMasterProGL Installation: Confirm that the .exe file for PCMasterProGL has been successfully installed. If updating to a newer version, uninstall any previous versions using either the directory deletion method or the computer’s uninstallation tool. Ensure you return your PPK License before installing the new version.

  • Base Station File: For PPK processing, ensure that the Base Station file recorded during the flight is copied to the “data” folder for the project.

  • Inertial Explorer License: If using the Inertial Explorer license included with PCMasterProGL, confirm that your license is active on the computer.

  • RTK Corrections: For RTK workflows, verify that the payload received RTK corrections before recording. This requires an RTK modem.

  • IMU to Antenna Lever Arm Offsets: Make sure to record the IMU to Antenna Lever Arm Offsets and input them into the RESEPI web-GUI before data capture for accurate processing.